- Water Safe-1020 for cooling towers, Water Safe FC-70/90 for chiller and A/C de-scaling, Water Safe RO Antiscalant for membranes
- Screw chillers 50 to 2,000 TR, centrifugal chillers and cold storage design
- RO plants with UF pre-treatment and Zero Liquid Discharge (ZLD) systems
- On-site analysis and 24/7 technical support for water treatment customers
Cooling towers, chillers and RO plants all fail slowly through scale, corrosion, biological growth and membrane fouling. Seamens Enterprises supplies the Water Safe chemicals that control these problems and the plant itself, from cooling tower supply and chiller systems to RO plants and their erection.
Which water treatment chemicals does Seamens supply for cooling and RO?
| Product | What it does |
|---|---|
| Water Safe-1020 | Cooling tower dispersant that controls scale and biological fouling in open recirculating cooling systems, keeping heat exchangers clean and extending fill life. |
| Water Safe FC-70/90 | Two-way action organic de-scaler for chiller and A/C plant descaling; safe for copper and aluminium heat exchangers and does not require system shutdown for dosing. |
| Water Safe RO Antiscalant | Prevents membrane fouling and scaling in reverse osmosis systems, extending membrane life and maintaining permeate flow rates. |
| Cooling Tower Descaler | Organic-based descaling of cooling tower fill and heat exchangers. |
| RO Membrane Cleaner | Alkaline cleaning of RO and UF membranes. |
| Biofilm Remover | Elimination of biofilm in water systems and process pipelines. |
The Water Safe series is formulated and manufactured in Pakistan using imported premium raw materials. Water Safe FC-70/90 is certified by Luwa and Conair for use in their industrial air-handling, humidification and climate-control equipment installed across Pakistan.
Water Safe Series: German Based Organic Chemical Technologies
The Water Safe series covers air humidification and A/C plants, boilers, cooling towers, closed circuits and RO plants. Every product is supplied in 60 kg, 250 kg and 1,000 kg packs.
| Product | Application | Pack sizes |
|---|---|---|
| Water Safe FC-3020 | A/C plants: water re-circulating system | 60 kg, 250 kg, 1,000 kg |
| Water Safe FC-120Q | A/C plants: anti-scale and corrosion inhibitor | 60 kg, 250 kg, 1,000 kg |
| Water Safe FC-30B | A/C plants: water softener | 60 kg, 250 kg, 1,000 kg |
| Water Safe FC-7090 (FC-70/90) | A/C plants: organic de-scaler | 60 kg, 250 kg, 1,000 kg |
| Water Safe BR-111 | Boilers: anti-scalant | 60 kg, 250 kg, 1,000 kg |
| Water Safe BR-555 | Boilers: oxygen scavenger | 60 kg, 250 kg, 1,000 kg |
| Water Safe CT-9080 | Cooling towers: scale inhibitor | 60 kg, 250 kg, 1,000 kg |
| Water Safe DC-1020 | Cooling towers: dispersant | 60 kg, 250 kg, 1,000 kg |
| Water Safe BC-1000 | Cooling towers: biocide | 60 kg, 250 kg, 1,000 kg |
| Water Safe BR-999 | Closed circuits (chillers etc.) | 60 kg, 250 kg, 1,000 kg |
| Water Safe RC-1030 | RO plants: anti-scalant | 60 kg, 250 kg, 1,000 kg |
| Water Safe RD-4050 | RO plants: biocide | 60 kg, 250 kg, 1,000 kg |
Which cooling, chiller and RO plants does Seamens supply?
| Plant | Scope |
|---|---|
| Cooling tower supply and erection | FRP counter-flow towers, induced draft cooling towers, cooling tower fill media and nozzles, drift eliminators |
| Industrial chiller systems | Screw chillers (50 to 2,000 TR), centrifugal chillers, cold storage system design; air-cooled and water-cooled |
| Reverse osmosis (RO) plants | Single and double-pass RO systems, ultra-filtration pre-treatment, Zero Liquid Discharge (ZLD) systems |
| Erection and commissioning | Turnkey project execution, pipework and instrumentation, performance testing and validation |
How is an RO antiscalant dose calculated?
Multiply the target dose in ppm by the feed flow in m3/h to get grams per hour. A 4 ppm dose on a 10 m3/h feed is 40 g/h, or 960 g per day. Confirm the dose against your feed analysis and the product guidance, and try our RO antiscalant dosing calculator.
What support comes with a water treatment programme?
- On-site water analysis before a programme is proposed.
- Custom dosing recommendations for your tower, chiller or RO plant.
- Regular monitoring visits with readings and recommendations.
- 24/7 emergency technical support.
Read how to choose a supplier in our guide to cooling tower and RO chemical suppliers in Pakistan.